Click to enlarge image
|
Principle
The traditional filter type purifier is non-economical because you should discard filter and replace with a new one when it is clogged and because it cannot remove water and carbon. The ISP-type Purifier removes sludge (1st filter) and water (2nd filter), promoting the efficiency of the engine and reducing oil and maintenance cost because it's possible to clean and re-use.
In addition, the separated 1st and 2nd filter stops contamination of 2nd filter, and avoids inconvenience of traditional hand-operated draining thanks to its auto-discharging of the filtered water by its auto drain system Specifications
| Description\Model |
Unit |
ISP-600 |
ISP-1200 |
ISP-1800 |
ISP-2400 |
ISP-3000 |
| Filtering Capacity |
L/Hr |
600 |
1200 |
1800 |
2400 |
3000 |
| Filtration (sludge) |
μ |
10 |
| Water Filtering Capacity |
PPM |
5 |
| Temperature of to be filtered |
°C |
10-60 |
| 1st Filter (stainless) |
mm |
Ø140x500 |
Ø140x500 |
Ø140x600 |
Ø140x600 |
Ø140x700 |
| 2nd Filter (special coated fiber glass) |
mm |
Ø150x700 |
Ø200x700 |
Ø200x800 |
Ø200x800 |
Ø200x1000 |
| External Dimension |
Breadth |
mm |
734 |
854 |
854 |
994 |
994 |
| Length |
mm |
505 |
580 |
580 |
675 |
675 |
| Height |
mm |
1046 |
1046 |
1146 |
1146 |
1346 |
| Pipe Connection |
A |
15 |
20 |
20 |
25 |
25 |
| Trochoid Pump Motor Capacity |
Kw |
0.4 |
0.75 |
0.75 |
1.5 |
1.5 |
| Power Supply |
AC220/380/440V, 3Ø, 50/60Hz |
|
|
|
|
| |
|
|
|